FEATURES
- Sealed with an inert gas, ensuring freedom from aging and influences exerted by external environment.
- The twin contact and wiping effect assures outstanding contact reliability, probability of failure is extremely low.
- Quick action permits a larger make and break capacity and longer service life.
- Can switch both AC and DC, permitting direct control over a wide range from low level load to electromagnetic power load.
Medium-capacity type : 5V 1mA to 240VAC 0.5A (5A making)
NEMA Contact Ratings : C300 (AC) and Q150 (DC)
NEMA HP Ratings : 1/10HP (120Vac), 1/8HP (240Vac)
- Small surge/noise during switching of inductive load.
UL RECOGNIZED IN ACCORDANCE WITH USA AND CANADIAN STANDARDS File No. E159361
|
|
|
|
Contact Arrangement
|
|
1NO
|
|
Rated Continuous Current
|
|
3 A
|
|
Rated Operational Current (NEMA Pilot Duty) AC1
|
|
240V 0.5A (180W)
|
|
Rated Operational Current (NEMA Pilot Duty) DC2
|
|
115V 0.3A (69VA)
|
|
Maximum Making Current 3
|
|
240VAC 15A
|
|
Maximum Breaking Current AC4
|
|
240VAC 15A
|
|
Maximum Breaking Current DC5
|
|
115VDC 0.5A
|
|
Min. Operational Power Ratings6
|
|
24V 1mA
|
|
Withstand Voltage Across Contacts
|
|
500VAC for 1 minute
|
|
Insulation Resistance
|
|
109 Ω or greater
|
|
Initial Contact Resistance
|
|
500mΩ or less
|
|
Capacitance
|
|
0.5 PF or less
|
|
1 Where 240VAC, the rated operational current is set at 10 times this value upon making (PF: 0.6 to 0.7) and 1 times this value upon breaking (PF 0.3 to 0.4). Rated operational current 1A means 10A making and 1A breaking.
2 Where 115VDC is indicated, the current is set at 1 times making and 1 times breaking.
3 The maximum making current complies with JIS C 4531, and enables 100 times making at a power factor of PF: 0.7.
4 The maximum breaking current, by referring to JIS C 4531, is based on switching 25 times at PF: 0.4 (AC) cases for the large capacity element. For the medium capacity element, switching 25 times at PF: 0.4 (AC) case only.
5 The maximum breaking current, by referring to JIS C 4531, is based on switching 25 times at time constant t = 100ms (DC) for either 115/230VDC cases for the large capacity element. For the medium capacity element, switching 25 times at time constant t = 40ms for 115VDC case only.
6 Where 24V 1mA is in circuit with optcoupler, 5V 10mA can be used.
|
|
|
|
|
|
|
|