Designed for High Temperature, High Humidity Atmosphere; Best among Non-Contact Types. Assuring 130C for Continuous Duty or 180 C for Short Time
Typical Applications
Continuous casting machines, coke ovens.converters, rolling mills, cement curing ovens, refrigerator's internal equipment.
Influence of Ambient Temperature, and Compensation
Where temperature varies widely from the beginning and dur ing operation, the actuating point and return point may change somewhat due to thermal characteristic of the magnetic unit.
For applications requiring higher accuracy, make the compen sation first before mounting.