Unsurpassed Performance at High Temperature, Humidity Atmosphere,
Exceeding any Non-Contact Types
130 °C Continuous, or 180 °C for Short Time
- Direct control of 100 VDC or greater, no power supply unit or amplifying relay needed
- No erroneous operations or break in circuit due to noise and/or surge
- Contactless design assures long service life and maintenance free operation
Typical Applications
Continuous casting machines, coke ovens, converters, rolling mills, cement curing ovens, refrigerators internal equipment.
Influence of Ambient Temperature, and Compensation
Where temperature varies widely from the beginning and during 3 operation, the actuating point and return point may change a little due to thermal characteristic of the magnetic unit. Therefore, for applications requiring higher accuracy, make the compensa tion first before mounting.
As for ratings and specifications other than those below, refer to those of standard type in category "Vane Type (PSMO)".